What is an E1 Error Code? - MRCOOL DIY Ductless Mini Split • Ingrams Water & Air (2024)

If an E1 error code shows up in your air handler, that means there is a communication error either with the indoor unit or the outdoor unit. The causes for this could be a wiring mistake, or a faulty control board with the indoor unit or the outdoor unit.

Troubleshooting An E1 Error Code

One thing you can do to try and troubleshoot the E1 error code is power off the MRCOOL DIY mini split then wait two minutes and restart it. If the E1 error code displays again, however, you may want to measure the unit's voltage. If you are not comfortable working with electricity, you may want to call MrCool tech support at270-366-0457.For the outdoor unit, take off the side wiring cover with a screw driver. Then, using a multi-meter, test the voltage. For a unit running off of 120 volts, touch the ends to L1 and Ground. For a unit running off of 240 volts, you will want to touch the ends to L1 and L2.For the indoor unit, you will want to place the ends of the multi-meter on 1 and 2 to make sure the unit is getting voltage. For a 120 volt unit, you will want to go between 1 and Ground. Doing these things will help you determine if the unit is wired correctly. If it is not a wiring issue, it is possible your control board may need to be replaced in either the indoor unit or the outdoor unit.This is when it is important to call the MRCOOL Warranty Department so they can help you determine the reason for the E1 error code.

Other MrCool DIY Error Codes

  • E0 - Indoor unit EEPROM parameter error
  • E1 - Indoor / outdoor units communication error
  • E2 - Zero-crossing signal detection error
  • E3 - Indoor fan speed has been out of control
  • E4 - Indoor room temperature sensor T1 open circuit or short circuit
  • E5 - Evaporator coil temperature sensor T2 open circuit or short circuit EC - Refrigerant leakage detection
  • F0 - Overload current protection
  • F1 - Outdoor ambient temperature sensor T4 open circuit or short circuit
  • F2 - Condenser coil temperature sensor T3 open circuit or short circuit
  • F3 - Compressor discharge temperature sensor TP open circuit or short circuit
  • F4 - Outdoor unit EEPROM parameter error
  • F5 - Outdoor fan speed has been out of control
  • P0 - IPM malfunction or IGBT over-strong current protection
  • P1 - Over voltage or over low voltage protection
  • P2 - High temperature protection of IPM module or compressor top
  • P3 - Outdoor ambient temperature too low
  • P4 - Inverter compressor drive error
  • P5 - Indoor units mode conflict (multi-zone ONLY)
  • P6 - Low pressure protection(Only for 36K)
What is an E1 Error Code? - MRCOOL DIY Ductless Mini Split • Ingrams Water & Air (2024)
Top Articles
Latest Posts
Article information

Author: Aracelis Kilback

Last Updated:

Views: 6339

Rating: 4.3 / 5 (64 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Aracelis Kilback

Birthday: 1994-11-22

Address: Apt. 895 30151 Green Plain, Lake Mariela, RI 98141

Phone: +5992291857476

Job: Legal Officer

Hobby: LARPing, role-playing games, Slacklining, Reading, Inline skating, Brazilian jiu-jitsu, Dance

Introduction: My name is Aracelis Kilback, I am a nice, gentle, agreeable, joyous, attractive, combative, gifted person who loves writing and wants to share my knowledge and understanding with you.